The Philips DigitalDiagnost (and BuckyDiagnost) training course covers Philips latest DR (Digital Radiography) system as well as the Bucky-based BuckyDiagnost system.
The Diagnost course is a skills development course designed to provide the experienced service professional with the skills necessary to fully service and calibrate these single & dual detector systems. The DigitalDiagnost product is built on the BuckyDiagnost platform and can have a Optimus Generator or an M-Cabinet CXA Generator. System components that will be covered in this course include:
- TH (Height Adjustable Table)
- CS (Ceiling Suspension)
- FS (Fixed Stand for X-Ray tube)
- VM (Vertical Bucky, moveable)
- VS (Vertical Stand)
- M-Cabinet CXA (Generator, 65kW or 80kW)
- Optimus Rad (Generator, 65kW or 80kW)
Prerequisites
To attend this course, the service professional must have a good understanding of the principles gained through attending Phase II or two years equivalent experience in servicing RAD equipment.
Objectives
- Understand the similarities & difference between the DigitalDiagnost & BuckyDiagnost products
- Describe how factors are optimized to produce the highest quality digital images
- Describe the function of the basic components of each DigitalDiagnost digital radiographic & BuckyDiagnost radiographic units
- Perform the necessary performance monitoring and quality assurance procedures
- Perform all system calibrations and adjustments to maintain the highest quality images
- Evaluate circuit functions to facilitate troubleshooting
- Perform a complete and thorough preventive maintenance inspection on the unit
Tuition: $7995
Course Length: 1 Week
CEU's Awarded: 4 CEU’s
Dates:
- Nov 18-22, 2024
- Feb 17-21, 2025
- May 19-23, 2025
- Aug 25-29, 2025
- Dec 1-5, 2025
Need parts?
RSTI eXchange is your multi-manufacturer, multi-modality solution for diagnostic imaging replacement parts.
Request Parts
Course Outline
- Service Key access using AIAT
- Obtain service key
- Obtain service key reader
- Install IST
- Install and configure service key reader
- Charge & test service key
- Utilize student service key on training system
- Digital imaging process overview
- Basic terminology
- DigitalDiagnost system overview
- Release Versions
- R1–R4
- FPD’s
- Fixed Detector (Trixell Pixium 4600)
- SkyPlate
- Release Versions
- DigitalDiagnost system operation
- System specifications
- Lab Activities
- Basic system operation
- Sun Workstation (Sun Solaris OS) software
- Workspot (Kontron PC, Windows OS) workstation software
- Image acquisition
- Image viewer
- Screen considerations
- Technologist digital QC
- System documentation overview Installation
- Operations
- Workspot Workstation
- Sun Workstation (demo workstation)
- Service
- Schematics
- Lab Activities
- Image quality
- Signal to noise
- Resolution
- Contrast ratio
- MTF
- Flatfield/phantom IQ
- AEC
- System service
- Service software
- CS Service Mode
- AGenT (Access Generator Tool)
- GEST (Generator E Service Tool)
- XScope
- Service software
- Lab Activities
- Required tools and software Remove and replace covers and system panels
- AWS
- Operators console
- Generator
- AWS configuration
- Site planning and installation
- Network configuration
- Ethernet config
- CAN Network
- Troubleshooting internal networks
- System calibration
- Tube Adaption
- Tube Conditioning
- Functional checks
- System backups
- System restore
- Lab Activities
- Component location
- Schematic location
- Physical location
- Connector locations
- Fuse location/identification
- Preventive maintenance
- Error codes
- System diagnostics
- Lab Activities
- PM
- OEM Preventative Maintenance Procedures
- Diagnostics
- PM
- Image Chain – Image Detection
- Detector Calibration
-
- Detector correction
- Flatfield correction
-
- System service procedures
- Software reload
- Troubleshooting
- Options
-
- Networking
- Output devices
- Laser printer
- PACS
- RWS
- Media
- Input devices
- Modality worklist
- Lab Activities
- Software Load
- OS
- Applications
- Configure and test output devices
- Configure and test input devices
- Backup/Restore
- Ghosting/Cloning procedures
- Software Load
- Calibration methods
- Generator calibration
- Lab Activities
- AEC calibration
- Beam alignment
-
- Collimator format
- NICOL Collimator
- Detector gain
- Positioner calibration – Table detector
- Positioner calibration – Wallstand detector
- Collimator format
- System schematics
- Gantry
- Generator
- Troubleshooting
- System diagnostics
- Lab Activities
- Review system diagrams and communication
- Troubleshooting
- System diagnostics
-
- Access Error logs
- Central Listing
- Test Points
- LED’s
- Networking
- Power Distribution/Supplies
- Course review
- Course evaluation