Course Outline

Servicing the Lorad Multicare Platinum Breast Biopsy System

Overview

This course is designed to give the service professional the required information and the hands-on skills needed to make necessary alignments, diagnose service issues and make required repairs. Given the importance of this mammographic modality and the delicate nature of the procedure, the highest calibration standards must be maintained.

Prerequisites

To attend this course, the service professional must possess fundamental knowledge and understanding of the principles of Xray(Phase I), mammography and basic electronics.

Objectives

  • Describe the performance specifications of the Multicare table
  • Describe the performance specifications of the needle guidance section
  • Describe the performance specifications of the stereoguide system
  • Describe the performance specifications of the digital imaging system
  • Demonstrate an understanding of the various subsystems of the biopsy system
  • Perform the necessary performance monitoring and quality assurance tests and performance
  • Perform the necessary calibrations and adjustments to maintain the highest degree of accuracy for the biopsy system
  • Evaluate circuit and system functions to facilitate troubleshooting

Tuition: $2995

Course Length: 1 Week

CEU's Awarded: 8 CEU’s

Dates:

  • Aug 5-9, 2024
Register Course Schedule   Course Outline  
Need parts?

RSTI eXchange is your multi-manufacturer, multi-modality solution for diagnostic imaging replacement parts.
Request Parts

Course Outline

Day 1
  • System introduction
  • Specifications
    • Table
    • Stereo guide
    • Needle guidance
    • Digital imaging system
  • Knobology
  • Physical layout
  • Using system documentation
  • System installation
  • Turn-on and power distribution
  • Lab Activities
    • System operation
    • Cover removal
    • Component identification
    • System installation
    • Power supply verifications
Day 2
  • X-ray production system
    • Data port
    • kV control
    • mA control
    • Rotor control
  • Lab Activities
    • Verify and calibrate kV
    • Verify and calibrate mA
    • Rotor control verification
    • X-ray tube replacement
      procedure
Day 3
  • Table controls
    • Table motion
    • C-arm motion
    • Compression motion and force
    • Drive belt adjustment
  • Lamp control
  • Stage controls
    • X/Y/Z axis control interface
    • X/Y motor drive
  • Needle alignment
  • Lab Activities
    • Table travel limits calibration
    • Stage adjustment
      • Left/right/up/down/height
      • Z-azimuth
      • Breast platform
      • Needle gum holders
    • X-ray field adjustments
    • Final needle guidance alignment and checks
      • Pivot point
      • Compression trays
Day 4
  • DSM system
    • CCD module
    • X486/NT/ Pentium computers
  • Digital imaging theory
  • Lab Activities
    • Creating white/black calibration
      maps
    • Align CCD module to X-ray tube
    • Calculating coordinates
    • Final alignment checks
    • System troubleshooting
Day 5
  • Course review
  • Course evaluation
  • Final exam
  • To register for a course, fill out the information below or download our registration form.

    For information on travel expenses and hotel accommodations please see our full coverage package information.
  • Course Registration

  • Personal Information

  • Contact Information

  • This field is for validation purposes and should be left unchanged.

Please fill out the form below and we will contact you regarding replacement parts.

Send Me Course Updates