Course Outline

Siemens Luminos Agile

Overview

The Siemens AXIOM Luminos Agile training course covers Siemens latest DRF (Digital Radiography/Fluoroscopy) system. The AXIOM Luminos Agile course is a skills development course designed to provide the experienced service professional with the skills necessary to fully service and calibrate these digital flat panel R&F systems. The AXIOM Luminos Agile product utilizes the Polydoros F80 Generator. System components that will be covered in this course include:

  • PHS (Stand/R&F Table)
  • DIT (Digital Imaging Tower = Spotfilmer)
  • 3D (Ceiling Suspension)
  • BWS (Bucky WallStand)
  • Polydoros F80 Generator

Prerequisites

To attend this course, the service professional must have a good understanding of the principles gained through attending Phase II or two years equivalent experience in servicing RAD equipment.

Objectives

  • Understand the components of the AXIOM Luminos Agile system
  • Describe how factors are optimized to produce the highest quality digital R&F images
  • Describe the function of the basic components of each Luminos Agile unit
  • Perform the necessary performance monitoring and quality assurance procedures
  • Perform all system calibrations and adjustments to maintain the highest quality images
  • Evaluate circuit functions to facilitate troubleshooting
  • Perform a complete and thorough preventive maintenance inspection on the unit

Tuition: $8995

Course Length: 1 Week

Dates:

  • Apr 2-5, 2024
  • Oct 7-11, 2024
Register Course Schedule  
Need parts?

RSTI eXchange is your multi-manufacturer, multi-modality solution for diagnostic imaging replacement parts.
Request Parts

Course Outline

Day 1
  • Service Key access
  • Digital imaging process overview
  • Basic terminology
  • Digital imaging process overview
  • Basic terminology
  • Luminos Agile system overview
    • SYNGO PC interface
    • FPD’s
      • Fluoro: Pixium 5100
        • Trixell Pixium 4343R
      • Rad/Wireless: Pixium 5500 wi-D
        • Trixel Pixium 3543
  • Luminos Agile system operation
  • System specifications
  • Lab Activities
    • Basic system operation
    • 3D coordinate system
    • Syngo Workstation software
      • Image acquisition
      • Image viewer
      • Screen considerations
      • Technologist digital QC
  • System documentation overview
  • Operations
    • Syngo Workstation
  • Service
  • Schematics
  • Lab Activities
    • Image quality
    • Signal to noise
    • Resolution
    • Contrast ratio
    • MTF
    • Flatfield/phantom IQ
    • AEC
Day 2
  • System service
    • Service software
    • Service access
  • Lab Activities:
    • Required tools and software
    • Remove and replace covers and system panels
    • AWS
    • Operators console
    • Generator
  • SYNGO basics
  • AWS configuration
  • Site planning and installation
  • Network configuration
  • Ethernet config
    • CAN Network
    • Troubleshooting internal networks
  • System calibration
    • Tube Adjustment
    • Inverter Adjustment
    • mAs Adjustment
    • Dose Adjustment (Iontomat)
    • FD Calibration
    • kV (Voltage response)
    • Control Fluoro
    • Collimation Adaptation
  • Functional checks
  • System backups
  • System restore
  • Lab Activities
    • Component location
    • Schematic location
    • Physical location
    • Connector locations
    • Fuse location/identification
Day 3
  • Preventive maintenance
  • Error codes
  • System diagnostics
  • Lab Activities
    • PM
      • OEM Preventative Maintenance Procedures
    • Diagnostics
  • Image Chain – Image Detection
  • Detector Calibration
      • FD calibration
  • System service procedures
    • Software reload
    • System ghosting
    • Troubleshooting
    • Options
    • Networking
    • Output devices
      • PACS
      • Workstations
      • Media
      • Printers
    • Input devices
      • Modality worklist
  • Lab Activities
    • Software Load
      • OS
      • Applications
    • Configure and test output devices
    • Configure and test input devices
    • Backup/Restore
    • Ghosting/Cloning procedures
Day 4
  • Generator calibration
  • Position calibration
  • Lab Activities
    • Iontomat Dose (AEC) calibration
    • QA
      • IQAP
      • X-Ray Field
    • Stand adjustment
Day 5
  • System diagrams
    • AWS
    • Gantry
    • Generator
  • Troubleshooting
  • System diagnostics
    • Hardware Test
    • Stand Test
    • AXCS Test
  • Lab Activities
    • Review system diagrams and communication
    • Troubleshooting
    • System diagnostics
    • Access Error logs
    • Networking
    • Power Distribution/Supplies
  • Course review
  • Course evaluation
  • Final exam
  • To register for a course, fill out the information below or download our registration form.

    For information on travel expenses and hotel accommodations please see our full coverage package information.
  • Course Registration

  • Personal Information

  • Contact Information

  • This field is for validation purposes and should be left unchanged.

Please fill out the form below and we will contact you regarding replacement parts.

  • This field is for validation purposes and should be left unchanged.
Send Me Course Updates
  • This field is for validation purposes and should be left unchanged.